13
When connecting each power wire to the corresponding
terminal, follow the instructions “How to connect wiring
to the terminal” and fasten the wire securely tight with
the fixing screw of the terminal plate.
How to connect wiring to the terminal
a) For Indoor Unit
(1) Cut the wire end with a cutting pliers, then strip the
insulation to expose the wire about 9/32" (7 mm).
See the label (Fig. 28) near the terminal plate.
(2) Using a screwdriver, loosen the terminal screw on
the terminal plate.
(3) Insert the wire and tighten the terminal screw com-
pletely using a screwdriver.
b) For Outdoor Unit
I For solid core wiring (or F-cable)
(1) Cut the wire end with a cutting pliers, then strip the
insulation to expose the solid wire about 15/16" (25
mm). (Fig. 29)
(2) Using a screwdriver, remove the terminal screw(s)
on the terminal plate.
(3) Using the pliers, bend the solid wire to form a loop
suitable for the terminal screw.
(4) Shape the loop wire properly, place it on the termi-
nal plate and fix it securely with the removed termi-
nal screw using a screwdriver.
I For stranded wiring
(1) Cut the wire end with a cutting pliers, then strip the
insulation to expose the stranded wiring about 3/8"
(10 mm) and tightly twist the wire ends. (Figs. 30
and 31)
(2) Using a screwdriver, remove the terminal screw(s)
on the terminal plate.
(3) Using a ring connector fastener or pliers, securely
clamp each stripped wire end with a ring connector.
(Fig. 30)
(4) Place the ring connector wire, and replace and
tighten the removed terminal screw using a screw-
driver. (Fig. 32)
Solid wire
Loop
Insulation
Strip 15/16" (25 mm)
Fig. 29
STRIP
SIZE
9/32"
(7 mm)
(ACTUAL
SIZE)
Fig. 28
Stranded wire
Ring
connector
Strip 3/8" (10 mm)
Fig. 30
Screw
Ring connector
Terminal plate
Wire
Special
washer
Fig. 32
Screw and
special washer
Ring
connector
Wire
WARNING
Loose wiring may cause the
terminal to overheat or result
in unit malfunction. A fire
hazard may also exist. There-
fore, be sure all wiring is
tightly connected.
Twist wire ends
Fig. 31
05-326 AirCon_85264189988000 12/5/05 3:35 PM Page 13
Vista de pagina 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 24 25

Comentarios a estos manuales

Sin comentarios

Carrier Generatori elettrici manuali utente

La lista di Carrier Generatori elettrici prodotti contiene 14 manuali utenti per 10 modelli. Tutte le guide utenti pdf sono disponibili per essere scaricate o visionate online.

Cliccare su un alfabeto di seguito per far scorrere la lista completa dei modellif models starting with that letter

Modelli Tipo di Documento
12KW
Manuale del Proprietario   Carrier 12KW Owner`s manual, 68 pagine
Manuale dell'Operatore     Carrier 12KW Operator`s manual, 56 pagine
16JT080-150
Specifiche   Carrier 16JT080-150 Specifications, 128 pagine
17KW
Manuale del Proprietario   Carrier 17KW Owner`s manual, 40 pagine
Manuale del Proprietario   Carrier 17KW Owner`s manual, 72 pagine
2.4L
Manuale Utente   1993-97 ENGINE COOLING Cooling System Removal, 62 pagine
2.4L 35kW
Manuale del Proprietario   Carrier 2.4L 35kW Owner`s manual, 80 pagine
Manuale Utente   35 kW - HVACpartners, 4 pagine
2.4L 45kW
Manuale Utente   Residential and Commercial Generators, 20 pagine
Manuale di Riparazione   Carrier 2.4L 45kW Repair manual, 156 pagine
69UG15
Manuale Utente   Carrier 69UG15 User's Manual, 50 pagine
ASPAS1CCA007
Manuale del Proprietario   Carrier ASPAS1CCA007 Owner`s manual, 52 pagine
ASPASICCA007
Manuale Utente   Carrier ASPASICCA007 User's Manual, 24 pagine
ASPB07-1SI
Manuale Utente   Carrier ASPB07-1SI User's Manual, 8 pagine