Sanyo PLC-WXL46 Manual de usuario Pagina 20

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 24
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 19
PLC
-
WXE46/WXL46
Basic Serial Command Specifications
20/24
7. Status Read Command
7.1. Format
7.1.1. PC issues commands in format as below;
“CR” Command [CR]
Command1 characterSee Basic Status Read Command Table
7.1.2. When a projector receives the appropriate command, it returns a character line as the
required data.
Required Data [CR]
Required DataA character lineSee Basic Status Read Command Table
7.1.3. When the received data cannot be decoded, the projector returns “?” [CR].
7.2. Transfer Example
Get input mode for projector with basic commands
Commandissues a command of getting current input mode
PC Projector C” “R” “1” “CR”
Projector PC “1” “CR”
Processing Response
(A few ms1s)
Shows Computer 1 is selected
7.3. Status Read Command
CR0” [CR]
Detail
Get the projector’s operating status
Response
Acceptable
“%1” [CR]
%1
”00” = Power ON
“80” = Standby
“40” = Countdown in process
“20” = Cooling Down in process
“10” = Power Failure
“28” = Cooling Down in process due to Temperature Anomaly
“88” = Coming back after Temperature Anomaly
“24” = Power Save/Cooling Down in process
“04” = Power Save
“21” = Cooling Down is in process after Power off due to lamp
failure
“81” = Standby after Cooling Down due to lamp failure
Unacceptable
“?” [CR]
Vista de pagina 19
1 2 ... 15 16 17 18 19 20 21 22 23 24

Comentarios a estos manuales