Sanyo C2432 Manual de usuario

Busca en linea o descarga Manual de usuario para Acondicionadores de aire del sistema de división Sanyo C2432. Sanyo C2432 User's Manual [en] Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 17
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Contents
Page
IMPORTANT!
Please Read Before Starting.................................. 1
1. GENERAL.......................................................... 2
1-1. Tools Required for Installation (not supplied)
1-2. Accessories Supplied with Indoor Unit
1-3. Optional Copper Tubing Kit
1-4. Type of Copper Tube and Insulation Material
1-5. Field Wiring
1-6. Additional Materials Required for Installation
2. INSTALLATION SITE SELECTION................... 3
2-1. Indoor Unit
2-2. Outdoor Unit
3. HOW TO INSTALL THE INDOOR UNIT ........... 5
3-1. Remove the Rear Panel from the Unit
3-2. Make a Hole
3-3. Install the Rear Panel on the Wall
3-4. Remove the Grille to Install the Indoor Unit
3-5. Shape the Indoor Side Tubing
3-6. Wiring Instructions
3-7. Recommended Wire Length and Diameter
3-8. Wiring Instructions for Inter-unit Connections
3-9. Mounting
3-10. Drain Hose
Model Combinations
Combine indoor and outdoor units only as listed
below.
Indoor Unit Outdoor Units
KS2432A C2432
CL2432
Power supply: 60Hz, single-phase, 208/230V
INSTALLATION INSTRUCTIONS
– Split System Air Conditioner – COOL/DRY Model
Use this manual when installing combined
models of indoor unit KS2432A and outdoor
unit C2432 or CL2432 only.
On items not included in this manual, see the
Installation Instructions (No. 85464179694003)
packed in the outdoor unit model C2432 or
CL2432.
Units should be installed by a licensed contractor
according to local code requirements.
ATTENTION
4. REFRIGERANT TUBING.................................. 13
4-1. Indoor Unit Tubing
4-2. Outdoor Unit Tubing
4-3. Connecting Tubing between Indoor and
Outdoor Units
4-4. Insulation of Refrigerant Tubing
4-5. Taping the Tubes
4-6. Finishing the Installation
5. REMOTE CONTROL UNIT INSTALLATION
POSITION ......................................................... 16
5-1. Mounting on a Wall
In Canada
SANYO FISHER COMPANY SANYO Canada Inc.
A DIVISION OF SANYO NORTH AMERICA CORPORATION 300 Applewood Crescent
21605 Plummer Street Concord, Ontario
85264189704003 © SANYO 2003 Chatsworth, CA 91311 U.S.A. L4K 5C7, Canada
W
01-386 AirCon 12/11/01 4:48 PM Page a
Vista de pagina 0
1 2 3 4 5 6 ... 16 17

Indice de contenidos

Pagina 1 - INSTALLATION INSTRUCTIONS

ContentsPageIMPORTANT!Please Read Before Starting... 11. GENERAL...

Pagina 2 - IMPORTANT!

93-8. Wiring Instructions for Inter-unit Connections(1) Insert the inter-unit wiring (according to local codes)into the through-the-wall PVC pipe. Ru

Pagina 3 - 1. General

10When connecting each power wire to the correspondingterminal, follow the instructions “How to connect wiring tothe terminal” and fasten the wire sec

Pagina 4 - Outside drainage

113-9. Mounting Right-side tubing(1) Shape the refrigerant tubing so that it can easily gointo the wall hole. (Fig. 24)(2) Push the wiring, refriger

Pagina 5 - Min. 4 inches

123-10. Drain Hosea) The drain hose should be slanted downward to theoutdoors. (Fig. 28)b) Never form a trap in the course of the hose.c) If the drai

Pagina 6 - Cut at slight angle

134. Refrigerant Tubing4-1. Indoor Unit Tubing Rear-left tubingFor rear-left tubing, optional tube connection (C) (APR-EN46U1B) is necessary. Plea

Pagina 7 - Air intake grille

144-3. Connecting Tubing between Indoor andOutdoor Unitsa) Tightly connect the indoor side refrigerant tubingextended from the wall with the outdoor

Pagina 8 - Mounting slot

(2) Wrap the armoring tape from the bottom of the out-door unit to the top of the tubing where it enters thewall. As you wrap the tubing, overlap half

Pagina 9

165. Remote Control Unit Installation PositionThe remote control unit can be operated from either anon-fixed position or a wall-mounted position.To e

Pagina 10 - Cover plate

1IMPORTANT! Please Read Before StartingThis air conditioning system meets strict safety and operat-ing standards. As the installer or service person,

Pagina 11

21. GeneralThis booklet briefly outlines where and how to install theair conditioning system. Please read over the entire setof instructions for the

Pagina 12

31-6. Additional Materials Required for Installation1. Refrigeration (armored) tape2. Insulated staples or clamps for connecting wire(See local codes

Pagina 13

42-2. Outdoor UnitAVOID:● heat sources, exhaust fans, etc. (Fig. 4a)● damp, humid or uneven locations.DO:● choose a place as cool as possible.● choos

Pagina 14 - 4. Refrigerant Tubing

5IndoorsideOutdoorsideSet screws for transportation onlyRight-reartubing(recommended)Right tubingLeft-rear tublingFig. 6Fig. 7aCenter ofleft-reartubin

Pagina 15 - Narrow tube

63-3. Install the Rear Panel on the WallBe sure to confirm that the wall is strong enough to sus-pend the unit.See either Item a) or b) below dependi

Pagina 16 - Insulated tubes

7How to replace the grille(1) Close the flaps.(2) Reinstall the grille into the lower part while aligningits tabs on the upper part. (Fig. 15a) Insert

Pagina 17

83-7. Recommended Wire Length and DiameterRegulations on wiring diameter differ from locality tolocality. For field wiring requirements, please refer

Comentarios a estos manuales